Accenta/Optima Engineer’s Manual
33
Omit Allow & Double Knock
LED Keypad:
Press [CHIME] to toggle omit allow status on or off.
Press [9] to turn all omit allow zones on.
Press [0] to turn all omit allow zones off.
Press [OMIT] to enter into menu. LED 2 is on.
Press [2] to select Omit Allow.
Press zone number [1-8] to choose a particular zone.
Press the [zone number] or [CHIME] to toggle the omit allow
status on or off. The appropriate LED is on when the zone is
set up as omit allow. Default settings are off.
Press [RESET] twice to leave the menu.