Events description
The following is a list of all of the events and faults for which the system monitors. These are stored in the event
memory which may be viewed by the manager. Some of these events may be shown as the cause of an alarm
when the system is unset after an alarm. Some may be displayed in the fault lockout after an alarm.
EVENT Description
24 HOUR ALM
Logged when a 24 hour zone has operated.
AUX FTC
Logged when a Fail to communicate signal is received from
Auxiliary communication equipment
AntiC RESET Logged when the system is reset by means of an anti-code.
AUX FUSE FAIL
Logged when the 12V SPEAKER fuse has failed.
AUX FUSE OK
Logged when the 12V SPEAKER fuse is replaced after a failure.
BATTERY FAIL Logged when the on-load battery voltage falls below 10.8V.
BATTERY OK
Logged when the battery voltage has risen above 11.4V following
a battery failure.
BELL FUSE FAIL
Logged when the BELL/STROBE fused has failed.
BELL FUSE OK
Logged when the BELL/STROBE fuse is replaced after a failure.
BOX TAMPER
Logged when the general tamper loop or box tamper has opened.
BOX TAMPR OK
Logged when the general tamper loop or box tamper has closed.
CLEAR LOG
Logged when NVM fault log is reset.
CODE ENTRY
Logged when a valid code is entered by USER n.
CODE TAMPER
This is logged in either Day or Set modes when more than 5
unsuccessful attempts at entering a code have been made.
ENG ACCESS
Logged when the Engineer menu is used.
ENG FINISH
Logged when the Engineer menu is exited.
ENG'R RESET
Logged when the system is reset by an Engineer code.
ENTRY DEVIAT Logged during the entry period when an Immediate zone is
activated.
ENTRY START Logged in the set period when an entry/exit zone is opened which
causes the entry period to start.
FIRE ZONE Logged when a Fire zone is activated. Includes the zone number.
iD LINE OK
Logged when iD short circuit is removed.
iD SHORT
Logged when excessive current flows in the iD line indicating a
short circuit across the lines.
19
Captiv8-20
Intelligent Security & Fire Ltd
Kommentare zu diesen Handbüchern