
Engineering Manual
20 Captiv8 Engineering Manual Eng00 Issue 1a 03/06/04
With the system Unset…
Key in the Manager PIN code.
SET/UNSET SYSTEM?
To set the Captiv8-256 system, press 'YES'. To move on to another menu item
press 'NO'.
a) Omit Zones
Press 'NO'.
SET DATE AND TIME[--]
Press 'NO'.
OMIT ZONES[--]
Some of doors may be used only rarely. Opening them, even with the system
unset, may cause an alarm. To open these doors safely, omit them from the
system as shown below.
Enter the zone number to omit.
OMIT ZONES?[06]
FIRE DOORS
Press 'YES'
To reinstate zones, key in the number again.
Press 'YES'
Kommentare zu diesen Handbüchern